MetroVote 简体中文
公开试运行资料持续补充 · 名单日期见各选举页查看范围 ↗
SURREY · 固定版本 · PDF 第 4 页

Surrey planning report 7922-0137-00

这段原文取自本站留存的同一份 PDF,仅展示本条相关文本;官方在线版本可能更新。

Staff Report to Council Application No.: 7922-0137-00 Planning & Development Report Page 4 DEVELOPMENT PROPOSAL Planning Considerations  The applicant seeks to remove a detached shed and build a personal workshop in that location on the southwest portion of the property. The increased size of this accessory building is required for a functional workshop building and would increase the lot coverage on this property to 27% (454.04 square metres), above the current maximum of 20% (338.2-square-metres).  Based on the increase in lot coverage, the proposal would not be possible without removing 63.81 square metres of floor area (comprising the sites lot coverage) from the existing structures on-site.  The floor plans indicate that the finished accessory building will be used as a personal workshop. The RA-G zone does not permit a detached secondary suite. The City would not accept any Building Permit application that proposes habitable space or servicing connections for a secondary suite within the accessory building.  The siting of the replacement accessory building on the southwest corner of the property would not result in visual impacts on the neighbourhood. The site currently contains an accessory shed building and will continue to be screened from the public frontage (138A Street) by a fence. The building will be separated from surrounding properties by mature trees, fencing, and other landscaping.  The south abutting neighbor (whose property line borders the proposed accessory building) has indicated support for the subject variance and authorizes the removal of a protected tree on their property that the proposed works would impact. Referrals Engineering: The Engineering Department has no objection to the project. POLICY & BY-LAW CONSIDERATIONS Zoning By-law Lot Coverage Variance  The applicant is requesting the following variance: o to increase the maximum lot coverage of the RA-G Zone from 20% to 27%.  The subject variance to increase lot coverage from 20% to 27% is required to replace an existing shed with a proposed personal workshop.  The applicant is not proposing to increase the maximum building density permitted on the property.

非商业公共资料研究与事实报道;仅展示核对事实所需的已评估摘录及本站中文说明。版权归原作者或发布机构;不表示来源机构认可本站。原文、来源及使用条款见链接。 来源使用条款 ↗

打开官方 PDF ↗
版本与字符定位

留存文件 SHA-256:94bd92d2a4c55dc1cdfd1b0fdf402cbe0d4e318a75f2a7b90383b6c92121d24b

文本 SHA-256:18932cbfed818f7c2aba999c768e82760e406e82912a5491c54c6a0eb6ac8786

抽取:pymupdf-1.26.7-text-pages-v1
第 4–4 页;字符 3226–5439(末端不含)