While GHG emission intensity limits may vary slightly between building occupancies, the overall mechanical system implications at each ZCSC level are the same: • EL-1 only requires measurement and reporting of a building's modelled GHG emissions. • EL-2 can be achieved through electrification of either the domestic hot water system or the space heating system within the building. • EL-3 requires electrification of both space heating and domestic hot water systems. • EL-4 is the most stringent level, reflecting very low GHG emission intensities that can be achieved in an all-electric building connected to BC's electrical grid.