Staff Report to Council
Application No.: 7922-0207-00
Planning & Development Report
Page 8
DEVELOPMENT PERMITS
Hazard Lands (Steep Slope) Development Permit Requirement
•
The subject property falls within the Hazard Lands (Steep Slope) Development Permit Area
(DPA) in the OCP, given that the site contains steep slopes in excess of 20% gradient. The
Hazard Land (Steep Slope) Development Permit is required to protect developments from
hazardous conditions.
•
The subject property exhibits a gentle sloping terrain with an elevation difference from 30 to
37-metres across the southeast to the northwest tip of the property. Overall, the subject
property follows a gently sloping terrain of 7 degrees for about 21 linear meters measured from
the road frontage. Thereafter, the sloping terrain becomes more steepened with a slope angle
of 25 degrees. There is a retaining wall along the north property line.
•
A geotechnical report, prepared by Qiyan (Rick) Jiang, P. Eng., of Tetron Engineering Ltd and
dated July 20, 2023, was reviewed by staff and found to be generally acceptable to proceed.
The report was reviewed by staff and found to generally conform to the OCP Development
Permit guidelines for Hazard Lands. The applicant will be required to submit a peer review of
the Geotechnical Report, with the potential for some modification of the content of the report
still required (subject to the findings of the peer reviewer). The finalized geotechnical report
will be incorporated into the Development Permit.
•
The geotechnical report investigated issues related to slope stability and storm water drainage
to determine the feasibility of redeveloping the site. Thereafter, the report proposes
recommendations to ensure the ongoing stability of the slope.
•
The consultant has determined that the development is feasible provided that the
recommendations in their report are incorporated into the overall design of the site, including
a rear geotechnical setback of 7.5-metres. No rock pit, shed, in-ground pool, hot tub, sprinkler
system, nor material stockpiles are permitted within the geotechnical setback zone. No
grading or slope disturbance is permitted. The final site grading shall prevent concentrated
storm water from entering the natural slope.
•
Registration of a Section 219 Restrictive Covenant that requires the owner to develop the site
in accordance with the conditions in the geotechnical report is required as a condition of final
adoption.
•
At Building Permit stage, the Building Division will require Letters of Assurance from a
geotechnical engineer to ensure that the building plans comply with the recommendations in
the approved geotechnical report.